iCare MAIA TrueColor Microperimetry
iCare

iCare MAIA TrueColor Microperimetry

The iCare MAIA is a TrueColor microperimetry system that combines retinal sensitivity mapping, real-time fundus tracking at 25 Hz and non-mydriatic confocal fundus imaging in a single automated exam. By measuring macular function point by point while imaging the retina, it shows the functional impact of macular disease that structural imaging alone does not, which gives the doctor another way to show a patient how macular function is changing over time, and can support a more concrete conversation about treatment. With 60-degree TrueColor and infrared imaging, optional red-free, blue and red software, and customisable test grids, the MAIA gives retina and macular practices structure-function data for diagnosis, treatment monitoring and patient discussion.

MicroperimetryRetinal TrackingTrueColor

What it does

  • Microperimetry with automated retinal tracking at 25 Hz, compensating for fixation loss during the test
  • TrueColor confocal fundus imaging over a 60° field on a 5 MP sensor at 17 µm resolution
  • Non-mydriatic through pupils as small as 3 mm, at 28 mm working distance
  • Four preset grids: 10° and 6° three-ring patterns at 37 points, a 20° four-diagonal pattern at 41 points, and a 20° 10-2 pattern at 68 points
  • Custom grids via the built-in grid editor
  • Full threshold 4-2 with fixation analysis, suprathreshold with scotoma finder, and fixation-only testing
  • Six automatic operations including auto-retinal and auto-pupil tracking
  • 15" embedded multi-touch display; 1 Gbit Ethernet and 802.11ac/b/g/n Wi-Fi
  • Red-free, blue and red imaging available through optional software

Is it right for your practice?

Best fit

Retina practices, macular disease specialists and comprehensive offices managing AMD, diabetic macular edema or other macular pathology, where the question is how the disease affects vision rather than what it looks like.

Why consider it

Structural imaging shows the disease. Microperimetry measures retinal sensitivity point by point and maps it onto a TrueColor fundus image, with automated tracking at 25 Hz compensating for fixation loss during the test. iCare's materials support detection and monitoring of functional change, treatment-efficacy assessment, structure/function correlation, fixation analysis and progression reporting. In practice that gives the doctor another way to show a patient how macular function is changing over time, which can support a more concrete treatment conversation.

What to compare

Microperimetry is an addition to structural imaging, not a replacement for it; a practice without OCT should almost certainly buy that first. MAIA also needs a genuine macular case load to justify itself; if you are referring most macular management out, the instrument will sit idle.

Ask me about

Whether your macular volume supports it, how the reports fit the way you already document treatment response, and what the footprint means for your lane: it is 360 × 590 × 620 mm and 27 kg on the same chassis as the EIDON.

Specifications

iCare iCare MAIA TrueColor Microperimetry specifications
TechnologyTrueColor confocal microperimetry
Projection Field30°
Background Luminance4 asb
Maximum Luminance1000 asb
Dynamic Range36 dB
Stimulus SizeGoldmann III
Stimulus Duration200 ms
Retinal Tracking25 Hz automated
Test StrategiesFull threshold (4-2) with fixation analysis, Suprathreshold (4 fixed levels, Scotoma finder), Fixation only
Test Grids10° (37 pts), 6° (37 pts), 20° (41 pts), 20° 10-2 pattern (68 pts), Custom
Fundus FOV60°
Sensor Resolution5 MP (2592 × 1944)
Imaging ModalitiesTrueColor and Infrared; Red-free, Blue and Red via optional software
Optical Resolution17 µm
Min. Pupil Size3 mm (non-mydriatic)
Auto Refraction–12D to +15D
Display15" multi-touch
Connectivity1 Gbit Ethernet, Wi-Fi (802.11ac/b/g/n), USB export
StorageSSD 480 GB+
Light SourcesInfrared (825–870 nm) and white LED (440–650 nm)
Working Distance28 mm
Automatic OperationAuto-alignment, auto-focus, auto-retinal tracking, auto-pupil tracking, auto-exposure, auto-capture
Dimensions (W × H × D)360 × 590 × 620 mm / 14.2" × 23.2" × 24.4"
Weight27 kg / 59 lb
Power100–240 VAC, 50–60 Hz, 80 W
ClassificationIEC 60601-1 Class II, Type B

Specifications reviewed: 2026-09-05
Manufacturer source: iCare: iCare MAIA TrueColor Microperimetry.