Marco ARK-1 Series Autorefractor/Keratometers
Marco

ARK-1 Series Autorefractor/Keratometers

Three autorefractor/keratometers, one optical platform

The ARK-1 series covers three instruments (the ARK-1s, ARK-1a and ARK-1) sharing a Super Luminescent Diode light source that produces sharper images than LED and, importantly, reads accurately through many cataracts. They differ mainly in tracking sophistication and features: the 1s and 1a offer full X-Y-Z eye tracking, the ARK-1 offers Y tracking.

ARK-1 · 1a · 1sAuto Ref/K

What it does

  • Super Luminescent Diode source for sharper images than LED
  • Accurate data through many cataracts
  • X-Y-Z eye tracking on the ARK-1s and ARK-1a; Y tracking on the ARK-1
  • Large pupil zone imaging method up to 6 mm diameter
  • Keratometry with mire ring to reduce eyelid artifact
  • Accommodation measurement on the ARK-1s and ARK-1a
  • 6.5-inch full-color LCD screen

Is it right for your practice?

Best fit

Any practice doing pre-test, and particularly practices with an older patient population where media opacity makes autorefraction unreliable.

Why consider it

The cataract point is the one that matters clinically. An autorefractor that gives you nothing on a patient with significant lens changes has failed at exactly the moment you needed it, and the Super Luminescent Diode source is what makes readings possible through many cataracts. Keratometry uses a mire ring to reduce eyelid artifact, imaging covers a pupil zone up to 6 mm, and the series feeds the TRS refractors and the EPIC workstation directly, which removes transcription from pre-test.

What to compare

Within the series the practical difference is tracking and accommodation measurement: the 1s and 1a have full X-Y-Z tracking and accommodation measurement, the ARK-1 has Y tracking and does not. If your technicians are experienced and your volume is moderate, the ARK-1 is enough and the extra tracking is capability you are paying for twice. If you want the instrument to do more of the alignment work, the ARK-F takes that further than any of the three. And if counter space is your problem and not accuracy, the Tonoref II folds tonometry into the same footprint.

Ask me about

Which model your technicians would get the most from, and whether your EMR takes the data directly or needs a bridge.

Specifications

These are the published figures for the 1S. The other models in this family differ; ask me for the specification sheet on the one you are considering.

Marco ARK-1 Series Autorefractor/Keratometers specifications
Objective Spherical Refractive Error-30.00 to +25.00 D (VD = 12 mm) (0.01/0.12/0.25 D increments)
Cylindrical Refractive Error (Technical Details)0 to ±12.00 D (0.01/0.12/0.25 D increments)
Cylinder Axis0 to 180° (1°/5° increments)
Minimum Measurable Pupil Diameterø2 mm
Subjective Visual Acuity Measurements<0.1 / 0.1 / 0.25 / 0.32 / 0.4 / 0.5 / 0.63 / 0.8 / 1.0 / 1.25 <20/200 / 20/200 / 20/80 / 20/60 / 20/50 / 20/40 / 20/30 / 20/25 / 20/20 / 20/16
Spherical Refractive Error-20.00 to +20.00 D (VD = 12 mm) (0.25 D increments)
Near Addition Power0 to +9.75 D (0.25 D increments)
Corneal Curvature Radius5.00 to 13.00 mm (0.01 mm increments)
Corneal Refractive Power25.96 to 67.50 D (n = 1.3375) (0.01/0.12/0.25 D increments)
Corneal Cylindrical Power0 to ±12.00 D (0.01/0.12/0.25 D increments)
Corneal Cylinder Axis0 to 180° (1°/5° increments)
Pupillary Distance Measurement30 to 85 mm (1 mm increments)
Corneal Size Measurement10.0 to 14.0 mm (0.1 mm increments)Fixation TargetN/A
Pupil Size Measurement1.0 to 10.0 mm (0.1 mm increments)
Accomodation Measurement0 to 10.00 D (0.01/0.12/0.25 D increments)
Observation/Display Method6.5-inch color LCD
PrinterThermal line printer with auto cutter
Interface ConnectorsRS-232C: Two ports USB: One port LAN: One port
Power SupplyAC 100 to 240 V ±10% 50/60 Hz
Power Consumption100 VA
Measurements260 (W) mm / 495 (D) mm / 457 (H) mm
Mass20 kg

Specifications reviewed: 2026-09-06
Manufacturer source: Marco: ARK-1 Series Autorefractor/Keratometers.

Configurations and specifications change. Ask me to confirm before ordering.

Talk it through with me

Tell me how your practice handles this now and what you want it to do, and we can work through the options together. You do not need to have settled on a product first.